Frequently Asked Questions
Technical answers about NGS platforms, sequencing strategies, and genomics workflows from the Embryo team.
NGS requires PCR amplification of DNA fragments before sequencing, producing high accuracy but short reads. Third-generation sequencing (PacBio SMRT, Oxford Nanopore) sequences single molecules without amplification, producing longer reads but with different error profiles.
The choice depends on required throughput and read length. For 16S amplicon projects, MiSeq (2×300 bp) is standard. For RNA-seq and exome sequencing, NextSeq 2000 provides appropriate throughput. For large-scale WGS, NovaSeq 6000 or NovaSeq X is required. For rapid targeted sequencing with same-day turnaround, Ion Torrent may be appropriate despite its limitations in homopolymer accuracy. The key is to match the platform to the project scale rather than selecting a platform and designing the project around its limitations.
No. Roche discontinued the 454 platform in 2016. Active short-read platforms are Illumina and Ion Torrent. For long-read sequencing, PacBio and Oxford Nanopore are the available options.
Yes. Hybrid strategies that use Illumina short reads for depth and PacBio or Nanopore long reads for contiguity are standard for de novo genome assembly and comprehensive structural variant detection.
A single human WGS sample at 30× generates approximately 100 GB of FASTQ data plus 50 GB of aligned BAM files for downstream analysis and long-term storage. For a 100-sample project, plan for 15–20 TB of total storage including intermediate and output files. RNA-seq projects generate less data per sample — approximately 15–20 GB of FASTQ for 30 million reads — but the storage requirements still scale with sample number and must be budgeted accordingly.
Whole-genome sequencing reads the entire genome, including both coding and non-coding regions. Whole-exome sequencing targets only the protein-coding exons (~1–2% of the genome). WGS provides more comprehensive variant detection at higher cost; WES is more cost-effective for studies focused on coding variants.
Paired-end sequencing reads both ends of each DNA fragment, providing more accurate alignment, better detection of structural variants, and improved assembly quality. Single-end sequencing reads one end only and is lower cost. Paired-end is the standard for most NGS applications; single-end is used primarily for small RNA-seq and some tag-based methods where the fragment is shorter than the read length and additional information from the second read would be redundant.
Have a question not listed here?
Our bioinformatics team is happy to advise on sequencing strategy, platform selection, and project design.
Ask the Team